Even joints start with a prepared substrate. Adhesive is a poor way to compensate for a crooked wall while keeping the tiles in one plane. Choose compatible materials, check the surface and only then mix the adhesive. This guide covers ordinary interior work; showers, heating and difficult substrates require additional solutions.
Remove weak coatings, dust, grease and loose material. Place a long straightedge against the surface in several directions and check walls for plumb. Correct hollows and high spots beforehand with a suitable repair or levelling compound. Investigate cracks first: tiling does not remove the cause of substrate movement.
Screed and plaster must reach their specified strength and dry to the moisture level permitted for the system. Consult their documentation instead of judging readiness by a pale surface. Choose a primer for the substrate material and absorbency, and observe the specified waiting time before the next layer. Do not bond tiles to a dusty or crumbling surface.
Choose the finish before work begins: ceramic and porcelain tiles come in different formats. Decide on the tiles in advance so you can prepare the substrate and select a compatible adhesive that accounts for their size.
In bathrooms and showers, areas exposed to water need waterproofing beneath the tiles. Select it for the substrate and service conditions. Tiles and filled joints do not replace a separate protective layer. For a floor with a drain, plan the slope and connection to the drain in advance.
Apply the waterproofing according to the system instructions, observing the number of coats, coverage, thickness and waiting times. Treat corners, joints and pipe penetrations with compatible tapes and collars. Check the coating for damage before tiling: once covered, a defect will no longer be visible. Do not apply ordinary bathroom guidance to pools or permanently submerged surfaces.
For porcelain tile, look for an explicit statement that the adhesive is compatible with it. Consider tile size and weight, substrate material, waterproofing and underfloor heating. On walls, resistance to slipping matters. Approval for one format does not mean a product suits every large tile.
Prepare a straightedge, level, mixing container, mixer, flat and notched trowels, spacers, sponge and cutting tool. Choose notch size and permitted bed thickness according to the specific tile and adhesive recommendations. There is no single trowel for every job. Wear eye protection when cutting and use the dust extraction provided for the tool.
Before laying floor tiles, arrange a trial row with joints. Check the cuts at the threshold, walls and fittings, then mark reference lines. Plan your exit so you do not step on freshly laid tiles. Check the direction against your layout rather than the nearest wall, which may be uneven.
For a level wall installation, mark a horizontal line with a level. If starting from the second row, provide a secure support; cut and install the bottom row once the junction with the floor is ready. Fixing the support must not leave unsealed holes in the waterproofing. Confirm the positions of sockets and pipe penetrations before applying adhesive.
Measure water according to the instructions, mix the dry product until uniform and allow the stated resting time, if required. Mix only as much as you can use in time. Do not add water to restore the workability of adhesive that has begun to set.
Apply adhesive evenly: first work it into the substrate with the flat side of the trowel, then comb it with the notched side. Cover small areas within the open time, the period during which applied adhesive can still bond. Do not confuse this with the working life of the mix in the bucket. Remove adhesive that has dried on the surface and replace it with fresh material.
Set the tile, press it in and move it slightly to spread the adhesive. Periodically lift a freshly laid tile and check transfer to its back. If substantial voids remain, adjust the application and tool. Apply a contact coat to the tile as well where the system requires it. The required coverage depends on service conditions and may differ for walls, floors and wet areas. Separate dabs of adhesive do not provide even support.
Check the plane with a straightedge and level as you work, while adjustment is still permitted. A tile levelling system helps align the edges of neighbouring tiles. It does not fix an uneven substrate or replace a check of adhesive contact. Do not tighten clips so much that they pull the tile away from the adhesive.
Maintain joints of the specified width even with rectified tile, whose edges have been trimmed. Remove excess adhesive before it hardens, leaving room for grout. Do not rigidly fill the perimeter or specified movement joints with adhesive or ordinary cement-based mixture.
Grout after the waiting period specified for the adhesive. Test first on a sensitive surface. Fill clean joints with a rubber float and remove residue within the manufacturer's stated time using a well-wrung sponge. Too much water during cleaning can impair the result and cause uneven colour.
Use the specified flexible detail at bathroom corners and junctions with sanitary fixtures. Ordinary cement grout cannot replace sealant in such a joint.
Do not load the floor or wet the joints before the permitted time. Being able to walk on a surface does not mean it is ready for full loads or shower use. Start the heating according to the system instructions after the required waiting periods. Before starting, you can ask ITUM about compatibility between the selected tiles and installation materials; this helps establish a clear sequence and avoid rework.